Has he tried  VINPUT VMSG R00,... ?

________________________________

From: The IBM z/VM Operating System [mailto:ib...@listserv.uark.edu] On
Behalf Of Sergio Lima
Sent: 01 November 2010 14:39
To: IBMVM@LISTSERV.UARK.EDU
Subject: Re: Reply CONSOLE when run ZOS under ZVM


Hello Mike,
 
He said that when gove Begin, the System stay in WAIT (Don't do none).
So, He sent hte directory entry, may be some mistake here :
 
USER ZOS19 ZOS19 500M 1000M ABCDEFG     
 MACHINE ESA 2                          
 OPTION MAINTCCW LNKEXCLU               
 ACCOUNT MVS00001 SITE-01               
 STDEVOPT DASDSYS DATAMOVER LIBRARY CTL 
 IPL CMS                                
 XSTORE 1M                              
 CONSOLE 01F 3270 C                     
 SPOOL 00C 2540 READER *                
 SPOOL 00D 2540 PUNCH  A                
 SPOOL 00E 1403 A                       
 SPECIAL 0E20 CTCA                      
 SPECIAL 0E21 CTCA                      
 SPECIAL 0700 3270                      
 SPECIAL 0701 3270                      
 SPECIAL 0702 3270                      
 SPECIAL 0703 3270                      
 SPECIAL 0900 3270                      
 SPECIAL 0901 3270                      
 SPECIAL 0902 3270                      
 LINK MAINT 190 190 RR                  
 LINK MAINT 19D 19D RR                  
 LINK MAINT 19E 19E RR                  
 
Can you see please ?
 
Thanks again,
 
Sergio
 

 

________________________________

Date: Mon, 1 Nov 2010 10:29:02 -0400
From: pacemainl...@gmail.com
Subject: Re: Reply CONSOLE when run ZOS under ZVM
To: IBMVM@LISTSERV.UARK.EDU

I don't know why you are seeing a CP READ for a z/OS prompt. 
Is this terminal defined to z/OS as a console?

Since it's in a CP READ you may try entering Begin.  then try the R 0,I


On Mon, Nov 1, 2010 at 10:21 AM, Sergio Lima <sergiovm...@hotmail.com>
wrote:


        Hello Mark and George,
         
        First thanks very much from your help.
         
        He do there what you said, but still don't work.
         
        So he send the console , and I do a copy past :
         
        CP Q TERM

        LINEND  # , LINEDEL OFF, CHARDEL OFF, ESCAPE  " , TABCHAR OFF

        LINESIZE 080, ATTN OFF, APL OFF, TEXT OFF, MODE VM, HILIGHT OFF

        CONMODE 3270, BREAKIN GUESTCTL, BRKKEY PF12 , SCRNSAVE OFF

        AUTOCR ON , MORE 050 010, HOLD ON , TIMESTAMP OFF, SYS3270 OFF

        

        CP IPL A80 LOADPARM 0A82CS

         *IEA247I USING IEASYSCS FOR z/OS 01.09.00 HBB7740

         ISG313I SYSTEM IS INITIALIZING IN GRS NONE MODE.  RING OR STAR
CONFIGURATION KE
        YWORDS IN GRSCNF00 ARE IGNORED.

         IEA598I TIME ZONE = W.06.00.00

         IXC414I CANNOT JOIN SYSPLEX ADCDPL WHICH IS RUNNING IN MONOPLEX
MODE: CONFIGURA
        TION REQUIREMENT

         IXC404I SYSTEM(S) ACTIVE OR IPLING: ADCD

         H *   IXC420D REPLY I TO INITIALIZE SYSPLEX ADCDPL, OR R TO
REINITIALIZE XCF.  
          REPLYING I WILL IMPACT OTHER ACTIVE SYSTEMS.

        H Prompt text: R 00,

        

        

        

        

        

        

        

        

        

        

        

        

        

                                                                    CP
READ   ZVM_BRT   
         
        He can't responde to ZOS machine, because when entry the
command, receive :
         
        R 00,I                             
        HCPCMD001E Unknown CP command: R   
                                           
        Thanks,
         
        Sergio
         
        
         
        
________________________________

        Date: Mon, 1 Nov 2010 10:00:41 -0400
        From: george_he...@newyorklife.com 

        Subject: Re: Reply CONSOLE when run ZOS under ZVM
        
        To: IBMVM@LISTSERV.UARK.EDU
        
        
        Sergio: 
        
        You need to CP SET RUN ON which allows the z/OS guest virtual
machine to run without an interrupt for  CP READ. 
        
        
        
        
Mark Pace <pacemainl...@gmail.com> 
Sent by: The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>
11/01/2010 09:52 AM 
Please respond to
The IBM z/VM Operating System <IBMVM@LISTSERV.UARK.EDU>


To
IBMVM@LISTSERV.UARK.EDU         
cc
        
Subject
Re: Reply CONSOLE when run ZOS under ZVM        

                




        I'm not sure about his specific problem, but things to take into
account. 
        The default recall key for z/OS is PA1 which the default key for
CP READ. 
        A couple of things that I add to my USER DIRECT entry for all
z/OS guests. 
        
           COMMAND TERM BRKKEY PF12         
           COMMAND TERM BREAKIN GUESTCTL    
           COMMAND SET RUN ON               
        
        The BRKKEY will change the CP READ to PF12, leaving PA1 for z/OS
console recall. 
        Changing the BREAKIN to GUESTCTL will limit some of the times
that z/VM interupts the console 
        
        On Mon, Nov 1, 2010 at 9:38 AM, Sergio Lima
<sergiovm...@hotmail.com <mailto:sergiovm...@hotmail.com> > wrote: 
        Hello List,
         
        A friend have a question, but, his is not in this list, and for
this reason I try do a favour ask this question for him.
        He try run ZOS under ZVM, and when need give a response (reply),
the CMS machine stay under CP READ, and for this reason the IPL can't
continue.
        I said that give CP TERM CON 3270, but still don't run.
        Someone already have this problem?
         
        Thanks very much
         
        Sergio . 
        
        
        
        -- 
        Mark D Pace  
        Senior Systems Engineer  
        Mainline Information Systems  
        
        
        
        
        




-- 

Mark D Pace 
Senior Systems Engineer 
Mainline Information Systems 




Reply via email to