Through a FICON Director. ESCON CTC-CNC pairs can be through a director, too.

On Wed, Dec 22, 2010 at 5:18 AM, Shimon Lebowitz <[email protected]> wrote:
> Really? Wouldn't a FICON channel that is being used for CTC between LPARs
> need to have *both* ends attached to FICON cards in the computer, the way an
> ESCON
> CTC is built? How could it connect LPARs if one end goes to DASD or TAPE?
>
> I do not yet have FICON (till next month....) but I am interested in
> learning!
>
> Thanks,
> Shimon
>
>
> On Wed, Dec 22, 2010 at 7:36 AM, Riedel, Alexander
> <[email protected]> wrote:
>>
>> Hi Martha,
>>
>> it is not necessary to reserve some FICON Links for only CTC. You can
>> share them for DASD, TAPE and FICON-CTC.
>>
>> Kind regards,
>>
>> Alexander
>>
>>
>> -----Ursprüngliche Nachricht-----
>> Von: The IBM z/VM Operating System [mailto:[email protected]] Im
>> Auftrag von Martha McConaghy
>> Gesendet: Dienstag, 21. Dezember 2010 20:32
>> An: [email protected]
>> Betreff: ISFC connection between LPARs
>>
>> Its been a long while since I had to create an ISFC connection. We are
>> finally
>> getting a z10 and I need to create a link between the two main LPARs.  I
>> don't have ESCON adapters in this box and I'd really hate to use up a
>> couple of FICON just for a CTC connection between the 2 LPARs.
>>
>> Is there any other way to do this on a z10?
>>
>> Martha
>
>



-- 
Gregg Reed
"No Plan, survives execution"

Reply via email to