IOW what does the LOCAL statement in your RSCS CONFIGs specify?
--
Mike Harding
z/VM System Support

[email protected]
[email protected]
[email protected]
(925) 926-3179 (w)
(925) 323-2070 (c)
IM: VMBearDad (AIM),  mbhcpcvt (Y!)


The IBM z/VM Operating System <[email protected]> wrote on 02/07/2011
10:28:48 AM:

> From: Alan Altmark/Endicott/IBM@IBMUS
> To: [email protected]
> Date: 02/07/2011 10:30 AM
> Subject: Re: RSCS CTCA between a first and second level system...
> Sent by: The IBM z/VM Operating System <[email protected]>
>
> On Monday, 02/07/2011 at 11:53 EST, RPN01 <[email protected]> wrote:
> > The systems are "polar" and "npolar".
> >> DMTNCR916E Invalid NJE signon connection record received
>
> That message comes out because signon record contains
> - A node id that doesn't match the local system's expectation of who is
at
> the other end
> - The signon record is too long (unusual)
> - There is a feature mismatch (unusual)
> - syntax errors in the signon protocol (unusual)
>
> Alan Altmark
>
> z/VM and Linux on System z Consultant
> IBM System Lab Services and Training
> ibm.com/systems/services/labservices
> office: 607.429.3323
> [email protected]
> IBM Endicott

Reply via email to