Dear all, Thanks for the feedback.
1.) The VMMDISK class is NOT RACLISTED. 2.) The profile looks as stated below. 3.) I added LINADM to the permission list. 4.) Before LINADM was recycled, RACF told: ICH408I USER(LINADM ) GROUP(SYS1 ) NAME(###### CLONSET4.201 CL(VMMDISK ) INSUFFICIENT ACCESS AUTHORITY FROM CLONSET4.* (G) ACCESS INTENT(ALTER ) ACCESS ALLOWED(READ ) 5.) After I logged off LINADM and restarted everything was working fine. Kind regards, Florian rac rlist vmmdisk clonset4.* all CLASS NAME ----- ---- VMMDISK CLONSET4.*(G) LEVEL OWNER UNIVERSAL ACCESS YOUR ACCESS WARNING ----- -------- ---------------- ----------- ------- 00 LINUX NONE ALTER NO INSTALLATION DATA ----------------- NONE APPLICATION DATA ---------------- NONE SECLEVEL -------- NO SECLEVEL CATEGORIES ---------- NO CATEGORIES SECLABEL -------- NO SECLABEL AUDITING -------- FAILURES(READ) NOTIFY ------ NO USER TO BE NOTIFIED CREATION DATE LAST REFERENCE DATE LAST CHANGE DATE (DAY) (YEAR) (DAY) (YEAR) (DAY) (YEAR) ------------- ------------------- ---------------- 241 09 241 09 241 09 ALTER COUNT CONTROL COUNT UPDATE COUNT READ COUNT ----------- ------------- ------------ ---------- NOT APPLICABLE FOR GENERIC PROFILE USER ACCESS ---- ------ MAINT ALTER SYSPROG ALTER LINUX READ LINADM ALTER ID ACCESS CLASS ENTITY NAME -------- ------- -------- --------------------------------------- NO ENTRIES IN CONDITIONAL ACCESS LIST Ready; T=0.01/0.01 18:56:26