Bindu,

I'm sorry.  I misread your question.  Carlo's answer is much more to
the point than mine was.

B


On Friday 29 February 2008 00:06:28 Bindu R. wrote:
> Dear Bruce,
>
> Could you please tell me if there is an option to do the EXAFS fitting for
> a compound having the absorbing atoms at two inequivalent crystallographic
> sites.
>
> For example,
>
> In Ca3Co2O6 compound, the Co ion occupies two inequivalent crystallographic
> sites with the Co1-O bond distance at 1.960 and Co2-O at 2.09 Ang.
>
> How does one invoke the contribution of both the bond distances in the
> first shell fitting?
>
> Best regards
> Bindu
>
>
>
>
>
> Dr.Bindu R.
> Visiting Fellow
> DCMP&MS
> Tata Institute of Fundamental Research
> Homi Bhabha Road
> Colaba
> Mumbai-400 005
> India
> Mobile-919892536830
>
> ---------------------------------
>  5, 50, 500, 5000 - Store N number of mails in your inbox. Click here.



-- 
 Bruce Ravel  ------------------------------------ [EMAIL PROTECTED]