Hi Teck Kwang Choo,

                                      For PCA analysis you can use SixPack
data analysis package by Dr. Sam Webb available at
https://home.comcast.net/~sam_webb/sixpack.html.

                              Also you can use Dmeter by Dr Bruce Ravel
available at http://bruceravel.github.io/demeter/.

With best wishes

Dr Abhijeet Gaur




On Wed, Jul 2, 2014 at 12:52 PM, <ifeffit-requ...@millenia.cars.aps.anl.gov>
wrote:

> Send Ifeffit mailing list submissions to
>         ifeffit@millenia.cars.aps.anl.gov
>
> To subscribe or unsubscribe via the World Wide Web, visit
>         http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
> or, via email, send a message with subject or body 'help' to
>         ifeffit-requ...@millenia.cars.aps.anl.gov
>
> You can reach the person managing the list at
>         ifeffit-ow...@millenia.cars.aps.anl.gov
>
> When replying, please edit your Subject line so it is more specific
> than "Re: Contents of Ifeffit digest..."
>
>
> Today's Topics:
>
>    1. spam on our mailing list (Bruce Ravel)
>    2. Re: to use scattering path in different model or to construct
>       a new model which is the combination of different simple compound
>       (Bruce Ravel)
>    3. Principal Component Analysis (PCA) for XANES (Teck Kwang Choo)
>    4. Re: Principal Component Analysis (PCA) for XANES
>       (Amayri, Dr. Samer)
>
>
> ----------------------------------------------------------------------
>
> Message: 1
> Date: Tue, 01 Jul 2014 13:31:59 -0400
> From: Bruce Ravel <bra...@bnl.gov>
> To: XAFS Analysis using Ifeffit <ifeffit@millenia.cars.aps.anl.gov>
> Subject: [Ifeffit] spam on our mailing list
> Message-ID: <53b2f08f.7000...@bnl.gov>
> Content-Type: text/plain; charset=ISO-8859-1; format=flowed
>
>
> Hi all,
>
> Over the years we've done a pretty good job of keeping spam off this
> mailing list.  As you saw, one slipped through this afternoon. Hopefully
> it was a one-time event and it will not be necessary to change the
> friendly nature of security on the list.
>
> B
>
> --
>   Bruce Ravel  ------------------------------------ bra...@bnl.gov
>
>   National Institute of Standards and Technology
>   Synchrotron Science Group at NSLS --- Beamlines U7A, X24A, X23A2
>   Building 535A
>   Upton NY, 11973
>
>   Homepage:    http://xafs.org/BruceRavel
>   Software:    https://github.com/bruceravel
>
>
> ------------------------------
>
> Message: 2
> Date: Tue, 01 Jul 2014 15:16:20 -0400
> From: Bruce Ravel <bra...@bnl.gov>
> To: XAFS Analysis using Ifeffit <ifeffit@millenia.cars.aps.anl.gov>
> Subject: Re: [Ifeffit] to use scattering path in different model or to
>         construct a new model which is the combination of different simple
>         compound
> Message-ID: <53b30904.5030...@bnl.gov>
> Content-Type: text/plain; charset=ISO-8859-1; format=flowed
>
> On 07/01/2014 10:43 AM, ZHAN Fei wrote:
> > 1 In the example,multiplet scattering path comes from two model
> > respectively,if use path from different model in different shell's
> > fit,there is risk of ignore important multiple path across models.Should
> > construct a cluster ,run feff to ensure?
>
> I don't completely understand the question, but I'll give it a try.
>
> In the example of Shelly's paper, she had a situation where she
> *couldn't* write a single feff.inp file.  Her local environment was the
> average of all possible ways that the uranyl ion could bond to biomass.
>   The uranyl binding disproportionated into a pH-dependent mixture of
> carboxyl, phosphoryl, and hydroxyl sites.  There was simply no way to
> write a feff.inp file for that.  So her solution was to run Feff more
> than once, picking and choosing paths that represented her best guess
> for modeling the average bonding environment.
>
> I think what you are really getting at, though, is whether it was right
> for Shelly to use parts of Feff calculations on a crystals to model
> something else.  If you were to read up on the theory used in Feff, you
> would find that the important thing is that the muffin tin radii of the
> scatterers get calculated reasonably.  Unless Shelly had a reason to
> think that the interatomic distances in her biomass sample were VERY
> different than in the crystals she used to run Feff, then the scattering
> amplitudes and phase shifts were almost certainly computed quite well
> enough.
>
> > 2 I have confusion of the relationship pf N between single path and
> > multiple path,for example I think U-Oe-C U-Oe-Pshould be 1 2
> > respectively,instead 2 4 in paper.
>
> I think Scott's explanation is correct.  In real-space,
> multiple-scattering theory, both ways around a three-legged path have to
> be counted.
>
> B
>
>
> --
>   Bruce Ravel  ------------------------------------ bra...@bnl.gov
>
>   National Institute of Standards and Technology
>   Synchrotron Science Group at NSLS --- Beamlines U7A, X24A, X23A2
>   Building 535A
>   Upton NY, 11973
>
>   Homepage:    http://xafs.org/BruceRavel
>   Software:    https://github.com/bruceravel
>
>
> ------------------------------
>
> Message: 3
> Date: Wed, 2 Jul 2014 15:59:25 +1000
> From: Teck Kwang Choo <teck.kwang.c...@monash.edu>
> To: XAFS Analysis using Ifeffit <ifeffit@millenia.cars.aps.anl.gov>
> Subject: [Ifeffit] Principal Component Analysis (PCA) for XANES
> Message-ID:
>         <
> cahxrqwdt2lvasbvbuu7hmag0owcc9u8fkbchzdamyw14-uy...@mail.gmail.com>
> Content-Type: text/plain; charset="utf-8"
>
> Hi Everyone,
>
> Does anyone know what software I should use to perform a Principal
> Component Analysis (PCA) on my K-edge XANES spectra (for sulfur)? The
> reason I need to use this technique is because I have a couple of reference
> compound spectra but am not sure which of those I should use to fit my
> unknown sample spectrum.
>
> Any help is appreciated.
>
> Thanks and kind regards.
>
>
> Teck Kwang Choo
> PhD Candidate
> Department of Chemical Engineering
> Room 225, Building 36
> Monash University
> Mobile No.: 04-11489904
> -------------- next part --------------
> An HTML attachment was scrubbed...
> URL: <
> http://millenia.cars.aps.anl.gov/pipermail/ifeffit/attachments/20140702/afc4cff2/attachment-0001.htm
> >
>
> ------------------------------
>
> Message: 4
> Date: Wed, 2 Jul 2014 07:22:08 +0000
> From: "Amayri, Dr. Samer" <ama...@uni-mainz.de>
> To: "'XAFS Analysis using Ifeffit'"
>         <ifeffit@millenia.cars.aps.anl.gov>
> Subject: Re: [Ifeffit] Principal Component Analysis (PCA) for XANES
> Message-ID:
>         <
> ab4ba6d33c596041b4d27dc9ffd88f2d5b6e9...@e14mdb-01.zdv.uni-mainz.de>
> Content-Type: text/plain; charset="utf-8"
>
> Hallo Teck,
>
> To get the Principal Component Analysis (PCA) program you can contact Dr.
> Andr? Ro?berg (rossb...@esrf.fr).
>
> Heir some references related to ITFA:
> Rossberg, A., Reich, T. & Bernhard, G. (2003). Analytical and
> Bioanalytical Chemistry 376, 631-638.
> Scheinost, A. C., Rossberg, A., Marcus, M., Pfister, S. & Kretzschmar, R.
> (2005). Physica Scripta T115, 1038-1040.
> Ikeda, A., Hennig, C., Rossberg, A., Tsushima, S., Scheinost, A. C. &
> Bernhard, G. (2008). Analytical Chemistry 80, 1102-1110.
> Rossberg, A., Ulrich, K. U., Weiss, S., Tsushima, S., Hiemstra, T. &
> Scheinost, A. C. (2009). Environmental Science &
> Technology 43, 1400-1406.
> Breynaert, E., Scheinost, A. C., Dom, D., Rossberg, A., Vancluysen, J.,
> Gobechiya, E., Kirschhock, C. E. A. & Maes, A. (2010).
> Environmental Science & Technology 44, 6649-6655.
>
> With best regards
>
> Dr. Samer Amayri
>
>
>
> From: ifeffit-boun...@millenia.cars.aps.anl.gov [mailto:
> ifeffit-boun...@millenia.cars.aps.anl.gov] On Behalf Of Teck Kwang Choo
> Sent: Wednesday, July 02, 2014 7:59 AM
> To: XAFS Analysis using Ifeffit
> Subject: [Ifeffit] Principal Component Analysis (PCA) for XANES
>
> Hi Everyone,
> Does anyone know what software I should use to perform a Principal
> Component Analysis (PCA) on my K-edge XANES spectra (for sulfur)? The
> reason I need to use this technique is because I have a couple of reference
> compound spectra but am not sure which of those I should use to fit my
> unknown sample spectrum.
> Any help is appreciated.
>
> Thanks and kind regards.
>
>
> Teck Kwang Choo
> PhD Candidate
> Department of Chemical Engineering
> Room 225, Building 36
> Monash University
> Mobile No.: 04-11489904
> -------------- next part --------------
> An HTML attachment was scrubbed...
> URL: <
> http://millenia.cars.aps.anl.gov/pipermail/ifeffit/attachments/20140702/41d07580/attachment.htm
> >
>
> ------------------------------
>
> _______________________________________________
> Ifeffit mailing list
> Ifeffit@millenia.cars.aps.anl.gov
> http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
>
>
> End of Ifeffit Digest, Vol 137, Issue 4
> ***************************************
>



-- 
Dr. Abhijeet Gaur
_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit

Reply via email to