Hi Maryline,

Use a = b = c = 10, with alpha = beta = gamma = 90. Now enter the coordinates 
from your simulation in units of angstroms/10 (which happens to be nm).

—Scott Calvin
Sarah Lawrence College

On Jun 1, 2015, at 10:43 AM, M Ferrier 
<mferr...@hotmail.com<mailto:mferr...@hotmail.com>> wrote:

Hi,

I am trying to create an Atoms input file for actinium. Since not a lot is 
known about this element we run some DT calculations. One molecule of Ac 
acetate in a box surrounded by water.
I have the coordinate of each elements. I was told the symmetry was P1 (I guess 
for the box) but unfortunately their is no symmetry in liquid and thus we 
cannot input the cell parameters (distances a, b, c and angles alpha, beta, 
gamma). I was wondering if their were a way to make Atoms run to obtain the 
Feff calculations. Or we should use a different model with a known solid?

Thank you for your help

Maryline Ferrier
_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov<mailto:Ifeffit@millenia.cars.aps.anl.gov>
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit

_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit

Reply via email to