Dear Abdallah,

It is often quite reasonable to fix two paths debye waller factors to be the 
same if they are the same atom at similar distances. However there is a slight 
problem with what you are trying to do. Because EXAFS is a sum of sine waves 
the minimum distance it can resolve between two paths of the same atom type is 
Pi/2*Kmax where kmax is the maximum k value in your data. Hence if you are 
trying to fit separate paths of the same atom type 0.06 A apart you need data 
out to about 26 k.  

I think and no one has ever told me this is completely Ok the only way to get 
two distances from such an analysis is to assert that the difference between 
the path is a fixed value and thus refine the two paths with the same delta R 
(and probably the same debye wller factor) this in my experience works in some 
cases
Best regards
Fred Mosselmans

-----Original Message-----
From: Ifeffit <ifeffit-boun...@millenia.cars.aps.anl.gov> On Behalf Of 
ifeffit-requ...@millenia.cars.aps.anl.gov
Sent: 03 August 2022 18:00
To: ifeffit@millenia.cars.aps.anl.gov
Subject: Ifeffit Digest, Vol 234, Issue 2

Send Ifeffit mailing list submissions to
        ifeffit@millenia.cars.aps.anl.gov

To subscribe or unsubscribe via the World Wide Web, visit
        http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
or, via email, send a message with subject or body 'help' to
        ifeffit-requ...@millenia.cars.aps.anl.gov

You can reach the person managing the list at
        ifeffit-ow...@millenia.cars.aps.anl.gov

When replying, please edit your Subject line so it is more specific than "Re: 
Contents of Ifeffit digest..."


Today's Topics:

   1. Exafs spectra Fitting of WO3 nanoparticles (Abdallah Nassereddine)


----------------------------------------------------------------------

Message: 1
Date: Wed, 03 Aug 2022 14:40:44 +0200
From: Abdallah Nassereddine <abdallah.nasseredd...@esrf.fr>
To: ifeffit@millenia.cars.aps.anl.gov
Subject: [Ifeffit] Exafs spectra Fitting of WO3 nanoparticles
Message-ID: <ddfc8c51f227c914d472d4115733b...@esrf.fr>
Content-Type: text/plain; charset="utf-8"; Format="flowed"



Dear all,

Good morning,

I try to Fit EXAFS spectra of a sample composed of supported tungsten oxide ( 
WO3/ZSM-5) nanoparticles obtained by operando studies under gas (CH4, He) at 
750 ?C.

First, and after several trials, I analyzed the WO3 reference spectrum obtained 
at room temperature and I succeeded in determining the amplitude (S0) by using 
the monoclinic structure WO3 cif file.

Then, I used the value of this amplitude obtained to be able to fit the 
structural parameters (coordination number N, Debye-waller Factor, Interatomic 
distance) of WO3/ZSM-5 nanoparticles under gas, but I can't. 
  the best result I got was by selecting the first two shells (at 1.858 and 
1.919 Angstrom) of the monoclinic structure. However, with all the 
optimizations, the Debye-waller factor obtained for the second W-O shell
(1.919 Angstrom) is always negative, and if I don't take this shell into 
account, I completely lose my Fit.

Have any of you ever worked on this type of sample and might have an idea that 
would help me improve my Fit?

Thank you in advance,

Best regards,

Abdallah Nassereddine
-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
<http://millenia.cars.aps.anl.gov/pipermail/ifeffit/attachments/20220803/616a66ad/attachment-0001.htm>

------------------------------

Subject: Digest Footer

_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit


------------------------------

End of Ifeffit Digest, Vol 234, Issue 2
***************************************

-- 
This e-mail and any attachments may contain confidential, copyright and or 
privileged material, and are for the use of the intended addressee only. If you 
are not the intended addressee or an authorised recipient of the addressee 
please notify us of receipt by returning the e-mail and do not use, copy, 
retain, distribute or disclose the information in or attached to the e-mail.
Any opinions expressed within this e-mail are those of the individual and not 
necessarily of Diamond Light Source Ltd. 
Diamond Light Source Ltd. cannot guarantee that this e-mail or any attachments 
are free from viruses and we cannot accept liability for any damage which you 
may sustain as a result of software viruses which may be transmitted in or with 
the message.
Diamond Light Source Limited (company no. 4375679). Registered in England and 
Wales with its registered office at Diamond House, Harwell Science and 
Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom


_______________________________________________
Ifeffit mailing list
Ifeffit@millenia.cars.aps.anl.gov
http://millenia.cars.aps.anl.gov/mailman/listinfo/ifeffit
Unsubscribe: http://millenia.cars.aps.anl.gov/mailman/options/ifeffit

Reply via email to