It is most likely because each group in Athena has a unique energy grid
and, if you save the aligned data in one Ascii file lumping several groups
together, it will keep only one energy grid, corresponding to the first
group. Hence, alignment will not be kept (because alignment means that each
energy grid is shifted by the number you use in the alignment process but
the program will not save those grids). In order to save that
information you need to save each group as individual ascii file and then
import them in Origin or anything else with their corresponding energy
values, and it will be plotted correctly.

Anatoly
-------------------------------------------------------------------
Anatoly I. Frenkel
Professor
Department of Materials Science and Chemical Engineering
Affiliate Professor, Department of Chemistry
* Stony Brook University *
Stony Brook, NY 11794
Email:  anatoly.fren...@stonybrook.edu
<https://urldefense.us/v3/__https://mail.bnl.gov/OWA/redir.aspx?C=F6wCGt4adziN6IvpdRQ-rWdgy3Oaoif_x-0ybKTBGBlALcrWeszTCA..&URL=mailto*3ajgchen*40columbia.edu__;JSU!!G_uCfscf7eWS!fTYh_HfYafTMjjQV4lSRAAPVF9Vmc7ralnkvP21UDyD6_PTHSFhIhDRk5xUwGLcTSCJxKbX8hy_pFErUfPJ4A2aA9zoFAHm_RTObOiPgZKoKmg$
 >
https://urldefense.us/v3/__http://you.stonybrook.edu/frenkel__;!!G_uCfscf7eWS!fTYh_HfYafTMjjQV4lSRAAPVF9Vmc7ralnkvP21UDyD6_PTHSFhIhDRk5xUwGLcTSCJxKbX8hy_pFErUfPJ4A2aA9zoFAHm_RTObOiPR2OBS6A$
 
Co-Director and Spokesperson, Synchrotron Catalysis Consortium (SCC) at BNL
https://urldefense.us/v3/__http://you.stonybrook.edu/scc2__;!!G_uCfscf7eWS!fTYh_HfYafTMjjQV4lSRAAPVF9Vmc7ralnkvP21UDyD6_PTHSFhIhDRk5xUwGLcTSCJxKbX8hy_pFErUfPJ4A2aA9zoFAHm_RTObOiNczmgCcQ$
 

Joint Appointment:
Senior Chemist
Chemistry Division, *Brookhaven National Laboratory*
Upton, NY 11973
Email: fren...@bnl.gov
https://urldefense.us/v3/__https://www.bnl.gov/staff/frenkel__;!!G_uCfscf7eWS!fTYh_HfYafTMjjQV4lSRAAPVF9Vmc7ralnkvP21UDyD6_PTHSFhIhDRk5xUwGLcTSCJxKbX8hy_pFErUfPJ4A2aA9zoFAHm_RTObOiMLVy2a5Q$
 
-------------------------------------------------------------------


On Sat, Feb 1, 2025 at 5:14 PM Raspante, Fabio via Ifeffit <
ifeffit@millenia.cars.aps.anl.gov> wrote:

> Hi, I worked on some data and I aligned them properly before to do any
> comparison. I also checked the alignment by plotting all the data together.
> After that I exported the data to have a file usable on Origin (the .dat
> format) but the problem
> ZjQcmQRYFpfptBannerStart
> This Message Is From an External Sender
> This message came from outside your organization.
>
> ZjQcmQRYFpfptBannerEnd
>
> Hi,
>
>
>
> I worked on some data and I aligned them properly before to do any
> comparison.
>
> I also checked the alignment by plotting all the data together.
>
>
>
> After that I exported the data to have a file usable on Origin (the .dat
> format)  but the problem is that after plotting the data on Origin, they
> are not aligned anymore. Specifically one group of data is not aligned to
> the others.
>
>
>
> Do you know what could be the problem? And how can I solve it?
>
>
>
> Many thanks,
>
>
>
> Fabio
> ifeffit mailing list:
> https://millenia.cars.aps.anl.gov/mailman3/lists/ifeffit.millenia.cars.aps.anl.gov/
> to unsubscribe, send mail to ifeffit-le...@millenia.cars.aps.anl.gov
>
ifeffit mailing list:  
https://millenia.cars.aps.anl.gov/mailman3/lists/ifeffit.millenia.cars.aps.anl.gov/
to unsubscribe, send mail to ifeffit-le...@millenia.cars.aps.anl.gov

Reply via email to