Bharathi, When the device is being shown as disconnected, do a dmesg|tail and check if its showing a disconnection there. It should be H/W problem and need not be a generic one for their product. Perhaps just a faulty device. AFAIK the change in /dev entry usually occur only if there is a physical disconnection and there is no rule defined for the device in udev rules.
It _may_ not be a minicom issue. Check dmesg first. On Tue, May 4, 2010 at 11:18 AM, Kenneth Gonsalves <[email protected]>wrote: > On Tuesday 04 May 2010 10:33:47 am Bharathi Subramanian wrote: > > Bus 002 Device 002: ID 067b:2303 Prolific Technology, Inc. PL2303 Serial > > Port > > > > as far I know prolific is the driver which comes with linux systems to run > a > serial converter. And the port is /dev/ttyUSB0 > -- > regards > kg > http://lawgon.livejournal.com > _______________________________________________ > ILUGC Mailing List: > http://www.ae.iitm.ac.in/mailman/listinfo/ilugc > -- Regards, Mahesh M Happy hacking... _______________________________________________ ILUGC Mailing List: http://www.ae.iitm.ac.in/mailman/listinfo/ilugc