On Wednesday 24 Sep 2008, Yashpal Nagar wrote: > We have got a server with two array controllers P400 (built in card), > additional card P800 (PCI card), each connected with 8x146Gb SAS > drives.
> I installed RHEL 4.0, P400 appeared as /dev/cciss/c0d0 and P800 as > c1d0. All went nicely and installed GRUB on /dev/cciss/c0d0; It was > just warming up and again required me to re-install. Please explain "warming up" and what did you have to re-install? > This time P400 appearing as c1d0 and P800 as c0d0 during > installation. > Can the order be changed in the BIOS? Usually, the embedded controller appears first. > The only changed I can think of is: > a) opened the server to check Raid cache memory backup "battery" on > p400, whether present or not, No other change > b) made some changes into the BIOS relating to booting preference, NO > other change I think b) changed the order. -- Arun Khan _______________________________________________ ilugd mailinglist -- [email protected] http://frodo.hserus.net/mailman/listinfo/ilugd Archives at: http://news.gmane.org/gmane.user-groups.linux.delhi http://www.mail-archive.com/[email protected]/