> From: Ilwis Support
> Sent: Tuesday, October 05, 1999 9:16:39 AM
> To: Ilwis-List
> Subject: RE: tunnel tolerance
> Auto forwarded by a Rule
>
Dear Stefano,
Unfortunately, it is not possible to save/maintain the Tunnel Tolerance and
Snap Tolerance values (in meters) in the segment editor. Each time a segment
map is opened in the editor, default values are calulated:
Snap Tolerance: the default snap tolerance is calculated as: the largest
coordinate range, i.e. Xmax-Xmin or Ymax-Ymin as defined by the map's
boundaries, divided by 150.
Tunnel tolerance:the default tunnel tolerance is calculated as the largest
coordinate range, i.e. Xmax-Xmin or Ymax-Ymin as defined by the map's
boundaries, divided by 1500.
Kind regards,
Jelger Kooistra
-------------------------------------------
Jelger Kooistra, ILWIS Support Officer
ITC - ILWIS Department
PO Box 6, 7500 AA Enschede, The Netherlands
phone: +31 53 4874217 fax: +31 53 4874484
http://www.itc.nl/ilwis/dev/support
-------------------------------------------
> ----------
> From: Stefano C.A. Rossi[SMTP:[EMAIL PROTECTED]]
> Sent: Thursday, September 23, 1999 11:25:27 PM
> To: ilwis
> Subject: tunnel tolerance
> Auto forwarded by a Rule
>
> Dear ILWIS users,
> it is possible to save and maintain the value of the item "tunnel
> tolerance" as, e.g., for the snap value?
> Thankyou
> Stefano Rossi
> Geologist