alter table .... move tablespace ....;atau
alter table .... move; (pada tablespace yg sama)

-- 
best regards
database specialist
http://www.dbs247.com


On Tue, Apr 28, 2009 at 2:32 PM, Andes Febrian <[email protected]> wrote:

> Dear gurus,
>
> mohon pencerahannya, di alert log database saya muncul error :
> Corrupt block relative dba: 0x00c10f3d (file 3, block 69437)
> Fractured block found during buffer read
> Data in bad block:
>  type: 6 format: 2 rdba: 0x00c10f3d
>  last change scn: 0x0000.04defeb0 seq: 0x1 flg: 0x06
>  spare1: 0x0 spare2: 0x0 spare3: 0x0
>  consistency value in tail: 0xf9ea0601
>  check value in block header: 0xb2ad
>  computed block checksum: 0x655
> Reread of rdba: 0x00c10f3d (file 3, block 69437) found same corrupted data
> Tue Apr 28 13:45:47 2009
> Corrupt Block Found
>         TSN = 2, TSNAME = SYSAUX
>         RFN = 3, BLK = 69437, RDBA = 12652349
>         OBJN = 49871, OBJD = 49871, OBJECT = MGMT_METRICS_RAW_PK, SUBOBJECT
> =
>         SEGMENT OWNER = SYSMAN, SEGMENT TYPE = Index Segment
>
> saya coba rebuild, tapi ternyata object ini adalah IOT objek,
> SQL> ALTER INDEX MGMT_METRICS_RAW_PK REBUILD;
> ALTER INDEX MGMT_METRICS_RAW_PK REBUILD
> *
> ERROR at line 1:
> ORA-28650: Primary index on an IOT cannot be rebuilt
>
> so bagaimana cara saya untuk mengatasi corrupted block / index ini ? apakah
> dengan re-create IOT ini ? bila memang iya, bagaimana cara nya ?
>
> Many Thanks,
> Andes
>
>


[Non-text portions of this message have been removed]

Kirim email ke