Hi Ron,

2017-10-30 16:13 GMT+01:00 Ron Bonica <[email protected]>:

> Jean-Michele,
>
> Thanks for the thoughtful review. I will post a new version addressing
> your comments today or tomorrow.
>
> Responses inline......
>
>                                      Ron
>
> <snip>
>
> >
> > 3.  ICMP Extended Echo Reply
> >
> > <snip>
> >
> > o  F (IPv4) - The F-bit is set if the A-bit is also set and IPv4 is
> running on the
> > probed interface.  Otherwise, the F-bit is clear.
> >
> > o  S (IPv6) - The S-bit is set if the A-bit is also set and IPv6 is
> running on the
> > probed interface.  Otherwise, the S-bit is clear.
> >
> > o  E (Ethernet) - The E-bit is set if the A-bit is also set and IPv4 is
> running on
> > the probed interface.  Otherwise, the E-bit is clear.
> >
> > <JMC>
> > Question:
> > Why IPv4 must also run to have the E-bit set?
> > Question:
> > Why the E-bit is not set if IPv4 is not running and IPv6 is running?
> > </JMC>
> [RB ]
>
> This was a typo. I meant to say:
>
>   0 E (Ethernet) - The E-bit is set if the A-bit is also set and Ethernet
> is running on the probed interface.  Otherwise, the E-bit is clear.
>

<JMC>
OK.
</JMC>


>
>
> >
> > 4.  ICMP Message Processing
> >
> > <snip>
> >
> >    o  Set the Code field as described Section 4.1
> >
> >    o  If the Code Field is equal to No Error (0) and the L-bit is clear,
> >       set the A-Bit.
> >
> >    o  If the Code Field is equal to No Error (0) and the L-bit is set
> >       and the probed interface is active, set the A-bit.
> >
> > <JMC>
> > Question:
> > Why the A-bit is not set when Code Field is equal to Multiple Interfaces
> > Satisfy Query (3) and the L-bit is clear? Question: Same question when
> L-bit is
> > set. </JMC>
> >
> > <snip>
> >
> [RB ]
>
> Error code 3 (Multiple Interfaces Satisfy Query) means that they query is
> ambiguous. Or, on other words, that two or more interfaces satisfy the
> match conditions specified by the query. So, we can't set the A, F, S or E
> bits because we don't know which interface the user is asking about.
>

<JMC>
But, even if this is ambiguous, IMHO, all the interfaces are active =>
A-bit should be set
And Error Code 3 returned to probing interface raises this is ambiguous.
Now, I am OK that F, S and E should be cleared to avoid any confusion
between the different interfaces.

Did I miss something?
</JMC>

<snip>