When a programming status desc is encountered on the rx_ring,
next_to_process is bumped along with cleaned_count but next_to_clean is
not. This causes I40E_DESC_UNUSED() macro to misbehave resulting in
overwriting whole ring with new buffers.
Update next_to_clean to point to next_to_process on seeing a programming
status desc if not in the middle of handling a multi-frag packet. Also,
bump cleaned_count only for such case as otherwise next_to_clean buffer
may be returned to hardware on reaching clean_threshold.
Fixes: e9031f2da1ae ("i40e: introduce next_to_process to i40e_ring")
Suggested-by: Maciej Fijalkowski <[email protected]>
Reported-by: [email protected]
Reported by: Solomon Peachy <[email protected]>
Closes: https://bugzilla.kernel.org/show_bug.cgi?id=217678
Tested-by: [email protected]
Tested by: Indrek Järve <[email protected]>
Signed-off-by: Tirthendu Sarkar <[email protected]>
---
drivers/net/ethernet/intel/i40e/i40e_txrx.c | 9 ++++++++-
1 file changed, 8 insertions(+), 1 deletion(-)
diff --git a/drivers/net/ethernet/intel/i40e/i40e_txrx.c
b/drivers/net/ethernet/intel/i40e/i40e_txrx.c
index 0b3a27f118fb..50c70a8e470a 100644
--- a/drivers/net/ethernet/intel/i40e/i40e_txrx.c
+++ b/drivers/net/ethernet/intel/i40e/i40e_txrx.c
@@ -2544,7 +2544,14 @@ static int i40e_clean_rx_irq(struct i40e_ring *rx_ring,
int budget,
rx_buffer = i40e_rx_bi(rx_ring, ntp);
i40e_inc_ntp(rx_ring);
i40e_reuse_rx_page(rx_ring, rx_buffer);
- cleaned_count++;
+ /* Update ntc and bump cleaned count if not in the
+ * middle of mb packet.
+ */
+ if (rx_ring->next_to_clean == ntp) {
+ rx_ring->next_to_clean =
+ rx_ring->next_to_process;
+ cleaned_count++;
+ }
continue;
}
--
2.34.1
_______________________________________________
Intel-wired-lan mailing list
[email protected]
https://lists.osuosl.org/mailman/listinfo/intel-wired-lan