On 2/13/2024 3:54 AM, Oleksij Rempel wrote:
> The i211 requires the same PTP timestamp adjustments as the i210,
> according to its datasheet. To ensure consistent timestamping across
> different platforms, this change extends the existing adjustments to
> include the i211.
> 
> The adjustment result are tested and comparable for i210 and i211 based
> systems.
> 
> Fixes: 3f544d2a4d5c ("igb: adjust PTP timestamps for Tx/Rx latency")
> Signed-off-by: Oleksij Rempel <[email protected]>
> ---

Reviewed-by: Jacob Keller <[email protected]>

Reply via email to