When booting with a dock connected, the igc driver can get stuck for ~40 seconds if PCIe link is lost during initialization.
This happens because the driver access device after EECD register reads return all F's, indicating failed reads. Consequently, hw->hw_addr is set to NULL, which impacts subsequent rd32() reads. This leads to the driver hanging in igc_get_hw_semaphore_i225(), as the invalid hw->hw_addr prevents retrieving the expected value. To address this, a validation check is added for the EECD register read result. If all F's are returned, indicating PCIe link loss, the driver will return -ENXIO immediately. This avoids the 40-second hang and significantly improves boot time when using a dock with an igc NIC. [ 0.911913] igc 0000:70:00.0: enabling device (0000 -> 0002) [ 0.912386] igc 0000:70:00.0: PTM enabled, 4ns granularity [ 1.571098] igc 0000:70:00.0 (unnamed net_device) (uninitialized): PCIe link lost, device now detached [ 43.449095] igc_get_hw_semaphore_i225: igc 0000:70:00.0 (unnamed net_device) (uninitialized): Driver can't access device - SMBI bit is set. [ 43.449186] igc 0000:70:00.0: probe with driver igc failed with error -13 [ 46.345701] igc 0000:70:00.0: enabling device (0000 -> 0002) [ 46.345777] igc 0000:70:00.0: PTM enabled, 4ns granularity Signed-off-by: Chia-Lin Kao (AceLan) <[email protected]> --- drivers/net/ethernet/intel/igc/igc_base.c | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/drivers/net/ethernet/intel/igc/igc_base.c b/drivers/net/ethernet/intel/igc/igc_base.c index 9fae8bdec2a7..54ce60280765 100644 --- a/drivers/net/ethernet/intel/igc/igc_base.c +++ b/drivers/net/ethernet/intel/igc/igc_base.c @@ -68,6 +68,10 @@ static s32 igc_init_nvm_params_base(struct igc_hw *hw) u32 eecd = rd32(IGC_EECD); u16 size; + /* failed to read reg and got all F's */ + if (!(~eecd)) + return -ENODEV; + size = FIELD_GET(IGC_EECD_SIZE_EX_MASK, eecd); /* Added to a constant, "size" becomes the left-shift value -- 2.43.0