On Thu, Feb 06, 2025 at 01:05:27PM +0000, Jagielski, Jedrzej wrote: > From: Andrew Lunn <[email protected]> > Sent: Tuesday, February 4, 2025 2:09 PM > >On Tue, Feb 04, 2025 at 08:17:00AM +0100, Jedrzej Jagielski wrote: > >> E610 NICs unlike the previous devices utilising ixgbe driver > >> are notified in the case of overheatning by the FW ACI event. > >> > >> In event of overheat when treshold is exceeded, FW suspends all > >> traffic and sends overtemp event to the driver. Then driver > >> logs appropriate message and closes the adapter instance. > >> The card remains in that state until the platform is rebooted. > > > >There is also an HWMON temp[1-*]_emergency_alarm you can set. I > >_think_ that should also cause a udev event, so user space knows the > >print^h^h^h^h^hnetwork is on fire. > > > > Andrew > > I am not sure whether HWMON is applicable in that case. > Driver receives an async notification from the FW that an overheating > occurred, so has to handle it. In that case - by printing msg > and making the interface disabled for the user. > FW is responsible for monitoring temperature itself. > There's even no possibility to read temperature by the driver
https://elixir.bootlin.com/linux/v6.13.1/source/drivers/net/ethernet/intel/ixgbe/ixgbe_sysfs.c#L27 ixgbe_hwmon_show_temp() is some other temperature sensor? Which you do have HWMON support for? Or is the E610 not really an ixgbe, it has a different architecture, more stuff pushed into firmware, less visibility from the kernel, no temperature monitoring, just a NIC on fire indication? Andrew