Thank you for your contribution! Sashiko AI review found no new issues
in this patch, but noticed 1 related pre-existing issue it does not
introduce:
- [Medium] ice: wrong port modulo in ice_tspll_bypass_mux_active_e825c()
  [1]
--

commit 54d93c3b2bb6d3588addc95fab52eae6473a669b
Author: Ivan Vecera <[email protected]>

ice: dpll: serialize changes of the SyncE CGU registers

This commit adds a mutex to struct ice_adapter to serialize read-modify-write
updates to the shared E825C SyncE CGU registers R10 and R11 across PFs.

> diff --git a/drivers/net/ethernet/intel/ice/ice_ptp.c 
> b/drivers/net/ethernet/intel/ice/ice_ptp.c
> index 7980eaf9ce253..449819cf8c879 100644
> --- a/drivers/net/ethernet/intel/ice/ice_ptp.c
> +++ b/drivers/net/ethernet/intel/ice/ice_ptp.c
> @@ -1368,7 +1368,9 @@ void ice_ptp_link_change(struct ice_pf *pf, bool linkup)
>                               break;
>                       }
>  
> +                     mutex_lock(&pf->adapter->cgu_synce_lock);
>                       err = ice_tspll_cfg_synce_ethdiv_e825c(hw, clk_pin);
> +                     mutex_unlock(&pf->adapter->cgu_synce_lock);
>                       if (active && err) {
>                               dev_err_once(ice_pf_to_dev(pf),
>                                            "Failed to configure SyncE ETH 
> divider for pin %d, err %d\n",

[Severity: Medium]
This problem wasn't introduced by this patch, but does
ice_tspll_bypass_mux_active_e825c() compute the wrong port index when setting
active here [1]?

drivers/net/ethernet/intel/ice/ice_tspll.c:ice_tspll_bypass_mux_active_e825c() {
    ...
        if (active_clk == port % hw->ptp.ports_per_phy +
                          ICE_CGU_BYPASS_MUX_OFFSET_E825C)
                *active = true;
    ...
}

ice_tspll_cfg_bypass_mux_e825c() programs the shared CGU mux with
port_num + ICE_CGU_BYPASS_MUX_OFFSET_E825C without reducing port_num modulo
ports_per_phy, and ice_dpll_rclk_update_e825c() checks it the same way.  On
dual-complex E825C, taking port % hw->ptp.ports_per_phy folds secondary
complex ports 4..7 onto 0..3, so a secondary complex port is never recognized
as active when selected and is falsely treated as active when the
corresponding primary complex port is selected.

[1] https://sashiko.dev/#/bug/linux-800face2-554f-486e-9268-16b7de29259d

-- 
Sashiko AI review ยท 
https://sashiko.dev/#/patchset/[email protected]?part=1

Reply via email to