On Nov 20, 2003, at 10:03 PM, Bennie Warren wrote:

I am trying to get some snmp variables that are Unsigned32. Below is the debug log output. Can this not be done?

19:02:21  pwas.lemoorenet.com.: ParseIfCounts:: Unknown link 0
SNMPReaderParseVariable: Unrecognized SNMP type: 71

Bennie:


According to SNMPv2-SMI, Unsigned32 is defined as [APPLICATION 2], which would be an SNMP type of 66 (0x42). This is the same as Gauge, and it is supported by InterMapper.

The SNMP type 71 (0x47) is [APPLICATION 7]. I don't know what that is. [APPLICATION 6] is the last thing defined in SMIv2 and that is Counter64; there is no [APPLICATION 7].

Which MIB are you using and what type of device is it?

Thanks,

Bill Fisher
Dartware, LLC
http://www.dartware.com


____________________________________________________________________
List archives: http://www.mail-archive.com/intermapper-talk%40list.dartware.com/
To unsubscribe: send email to: [EMAIL PROTECTED]

Reply via email to