At 8:50 AM -0500 4/11/08, Daniel Albaugh wrote:
I have a W2k box that I just installed IM Remote Access v4.6.9 on.  When I
launch the app, I get the following error message:

The procedure entry point MiniDumpWriteDump could not be located in the
dynamic link library dbghelp.dll


The problem is that Windows 2000 doesn't have by default a recent enough version of dbghelp.dll. If you've installed InterMapper for Windows somewhere, then you have a recent enough version of dgbhelp.dll in C:\Program Files\InterMapper (where C is whatever the startup disk is). Copy it to the directory where InterMapper_RemoteAccess.exe lives (C:\Program Files\InterMapper RemoteAccess, normally) and you should be all set.

Other ways to get a more recent version of dbghelp.dll are to download the debugging tools for Windows or to email me off-list ([EMAIL PROTECTED]) and ask me to send it to you.

The 5.0 installer for InterMapper RemoteAccess will fix this problem by installing the same copy of dbghelp.dll that InterMapper itself does.

-- Christopher

--
================================================
Christopher L. Sweeney
Dartware, LLC
http://www.dartware.com/
____________________________________________________________________
List archives: http://www.mail-archive.com/intermapper-talk%40list.dartware.com/
To unsubscribe: send email to: [EMAIL PROTECTED]

Reply via email to