George, Yes, Thank you! That really helps me to have a better understanding of the code flow. So, today I tried to observe oic.r.softwareupdate resource, get the endpoint and port, then oc_do_post the first step (isac) to check it will work or not. But it didn't work. And after I print the result of the oc_status code is 6 which meansĀ OC_STATUS_UNAUTHORIZED. Is it because of the permission of softwareupdate resources? Since it is the internal iotivity-lite framework? I've tried to use onboarding tool, choose option provision ACE2, set the resource href to /sw, give RUN permission. But it didn't work, I think I've done it wrong. Maybe you can help me how to give authorization to the client to interact with pstat and softwareupdate resource or how to set the permission of the internal Iotivity-lite framework (such as pstat and softwareupdate resource)?.
-=-=-=-=-=-=-=-=-=-=-=- Groups.io Links: You receive all messages sent to this group. View/Reply Online (#10365): https://iotivity.groups.io/g/iotivity-dev/message/10365 Mute This Topic: https://groups.io/mt/69378274/21656 Group Owner: [email protected] Unsubscribe: https://iotivity.groups.io/g/iotivity-dev/unsub [[email protected]] -=-=-=-=-=-=-=-=-=-=-=-