Hi Dmitry & all,

Attached is the patch file which is needed for *HPM*  Firmware Upgrade. 
***

2007-09-15
  - The HPM Spec indicates that whenever the long duration command is sent 
and
    if it returns the completion code of 0x80 (pending) we need to retry 
after
    minimum of 100 msec. The existing code was sending first upgrade 
status 
    immediately and then waiting for 100 msec interval. Added the code so 
that the
    first time when it sends Upgrade status it waits for some time (ie 100 
msec).
    Incase of Initiate Upgrade Action (upgrade mode) it waits for 500 msec 
to give
    enough time for IPMC to respond back.

  - Fixed a problem in displaying the Rollback version when Current 
version
    and file version were same.  ie "hpm check <filename>"

  - Fixed calling Initiate Upgrade action correctly for each component 
when only a
    single component is called.  ie "hpm upgrade <filename> component 
<ID>"

  - Fixed some printing stuff and also checking of typo-graphical errors 
when
    user gives "componetn" instead of "component"




Thanks,
Harshad Prabhu

Attachment: ipmi_hpmfwupg.patch