Thank you, Holger. That got me a bit further. I can now issue normal
commands remotely using 'intelplus'. The goal of this was to be able to use
'sol' but unfortunately I get this:

 ipmitool -E -o intelplus -C 3 -H 10.0.40.240 -U gadmin sol activate
Error: This command is only available over the lanplus interface

Does it sound like I won't be able to use sol at all on these machines?

Thanks again,
   Rob


On Tue, Apr 2, 2013 at 4:05 AM, Liebig, Holger <holger.lie...@ts.fujitsu.com
> wrote:

> Rob,****
>
> ** **
>
> You can try –o intelplus ****
>
> which takes some Intel BMC specifics during the RAKP handshake into
> account (given the fact that Intel is listed as the manufacturer of your
> BMC). ****
>
> ** **
>
> Good luck,****
>
> Holger****
>
> ** **
>
> *From:* Rob Cakebread [mailto:cakebr...@gmail.com]
> *Sent:* Friday, March 29, 2013 7:56 PM
> *To:* ipmitool-devel@lists.sourceforge.net
> *Subject:* [Ipmitool-devel] lanplus problem****
>
> ** **
>
> Hi,
>
> I'm able to use ipmitool with a remote machine using the 'lan' protocol,
> but 'lanplus' fails for every command. I'm trying to get SOL working, but
> I'm having no luck with lanplus at all:
>
> ipmitool -v -I lanplus -E -H 10.0.40.240 -U admin lan print
>
> Error in open session response message : insufficient resources for session
>
> Error: Unable to establish IPMI v2 / RMCP+ session
>
> I can ping the remote BMC with both ipmiping and rmpcping
>
> The machine is a Dell CS23, the BMC has IPMI v2. I'm using ipmitool
> v1.8.12 compiled from source.
> I've tried cold resetting the BMC, but it doesn't help.
>
> /ipmitool mc info
> Device ID                 : 32
> Device Revision           : 1
> Firmware Revision         : 0.09
> IPMI Version              : 2.0
> Manufacturer ID           : 343
> Manufacturer Name         : Intel Corporation
> Product ID                : 59 (0x003b)
> Product Name              : Unknown (0x3B)
> Device Available          : yes
> Provides Device SDRs      : no
> Additional Device Support :
>     Sensor Device
>     SDR Repository Device
>     SEL Device
>     FRU Inventory Device
>     IPMB Event Receiver
>     Chassis Device
> Aux Firmware Rev Info     :
>     0x0b
>     0x41
>     0x00
>     0x03****
>
>
------------------------------------------------------------------------------
Minimize network downtime and maximize team effectiveness.
Reduce network management and security costs.Learn how to hire 
the most talented Cisco Certified professionals. Visit the 
Employer Resources Portal
http://www.cisco.com/web/learning/employer_resources/index.html
_______________________________________________
Ipmitool-devel mailing list
Ipmitool-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/ipmitool-devel

Reply via email to