It is now possible to use iPXE to directly boot from an ISO image held on a 
SAN target (e.g. AoE, iSCSI, FCoE).  This has the same limitations as using 
memdisk to boot an ISO image, but without the memory overhead or initial 
download delay of memdisk.

There's no special syntax: just make the ISO image available on the SAN target 
and then attempt to boot from it (using "sanboot" or with a DHCP root-path).  
For example:

  (on server)  vblade 0 0 eth0 /path/to/winpe.iso
  (on iPXE)  sanboot aoe:e0.0

I have tested that WinPE and the VMware installer are able to start using this 
method.  I'd appreciate any further testing.

Michael
_______________________________________________
ipxe-devel mailing list
[email protected]
https://lists.ipxe.org/mailman/listinfo/ipxe-devel