Greetings,
It appears that the effort to rebuild the antenna farm this summer was
worthwhile. High winds took their toll last winter.
The antenna farm now consists of:
A 70 x 25 SW Super Loop @215 degrees
A 63 x 20 S EWE @130 degrees
A 90 x 25 NW EWE @320 degrees
A 70 x 19 NW EWE @330 degrees
A 60 x 25 NE EWE @50 degrees
Unterminated BOG 315'
Terminated BOG 285'
I also replaced the coax from my South EWE with auninterrupted run of new coax.
What a difference! I had various lengths of RG-52 connected via PL-259s &
barrel connectors. Even using the rubberized coating material, moisture
intrusion must have compromised the connectors over time. I noted a subpar
signal level from that antenna. The run of new coax solved that problem.
I originally configured the NE & S EWEs as Super Loops, but found the signal
levels a bit low, so I removed the ~960 ohm resistors and left the run of wire
along the ground to serve as a counterpoise ground. I have bedrock showing in
the backyard so my ground here is not very good.
Listening from 0443 to 0530 last night, I had more TA carriers than I have ever
noted before at this location:
774, 1044, 1134, 1215 (w/snivets of threshold audio), 1269, 1296, 1377, 1422 &
1575.
73
Craig Barnes
Wondervu, CO
Drake R8A
_______________________________________________
IRCA mailing list
[email protected]
http://montreal.kotalampi.com/mailman/listinfo/irca
Opinions expressed in messages on this mailing list are those of the original
contributors and do not necessarily reflect the opinion of the IRCA, its
editors, publishing staff, or officers
For more information: http://www.ircaonline.org
To Post a message: [email protected]