Jim,
My first experience with a 500' BOG was lackluster as well.  The culprit?
Location.
I laid the wire in the street gutter parallel to the street on which my
house sits.  It was deaf, most likely caused by rebar in the
concrete gutter.  I moved it 90' to the rear of the house into the dirt
alley and it worked FB and I was able to parallel a 335' BOG against it for
phasing and everything worked as advertised-side rejection and directivity
were definitely present.
73 Gil
_______________________________________________
IRCA mailing list
[email protected]
http://montreal.kotalampi.com/mailman/listinfo/irca

Opinions expressed in messages on this mailing list are those of the original 
contributors and do not necessarily reflect the opinion of the IRCA, its 
editors, publishing staff, or officers

For more information: http://www.ircaonline.org

To Post a message: [email protected]

Reply via email to