https://issues.apache.org/jira/browse/ARTEMIS-3079?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Clebert Suconic closed ARTEMIS-3079.
------------------------------------

> QueueControl fails on serializing AMQP messages with binary application 
> properties
> ----------------------------------------------------------------------------------
>
>                 Key: ARTEMIS-3079
>                 URL: https://issues.apache.org/jira/browse/ARTEMIS-3079
>             Project: ActiveMQ Artemis
>          Issue Type: Bug
>            Reporter: Domenico Francesco Bruscino
>            Assignee: Domenico Francesco Bruscino
>            Priority: Minor
>             Fix For: 2.17.0
>
>          Time Spent: 0.5h
>  Remaining Estimate: 0h
>
> The QueueControl fails to get the first message as JSON if the first message 
> of a queue is an AMQP message with binary application properties:
> {code:java}
> java.lang.IllegalArgumentException: AMQ219034: Params for management 
> operations must be of the following type: int long double String boolean Map 
> or array thereof but found org.apache.qpid.proton.amqp.Binary
>       at 
> org.apache.activemq.artemis.api.core.JsonUtil.addToObject(JsonUtil.java:214)
>       at 
> org.apache.activemq.artemis.api.core.JsonUtil.toJsonObject(JsonUtil.java:260)
>       at 
> org.apache.activemq.artemis.core.management.impl.QueueControlImpl.toJSONMsgArray(QueueControlImpl.java:95)
>       at 
> org.apache.activemq.artemis.core.management.impl.QueueControlImpl.toJSON(QueueControlImpl.java:88)
>       at 
> org.apache.activemq.artemis.core.management.impl.QueueControlImpl.getFirstMessageAsJSON(QueueControlImpl.java:916)
> ...
> {code}



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to