Timothy A. Bish commented on ARTEMIS-4666:
------------------------------------------

I don't think the broker test suite does any checks for Openwire specifically 
when using the Core federation bits.

Looking at the test sample you have supplied in Github I notice that you do not 
statically define the Queues in the broker configuration and I know from 
looking at the federation code that it is not always going to cope with that as 
one might think.  I'd recommend trying your tests after having defined the 
address and queues your sample is going to use and see if that allows it to 
pass.

> Federated queue consumers do not receive messages on classic clients
> --------------------------------------------------------------------
>
>                 Key: ARTEMIS-4666
>                 URL: https://issues.apache.org/jira/browse/ARTEMIS-4666
>             Project: ActiveMQ Artemis
>          Issue Type: Bug
>          Components: Federation
>    Affects Versions: 2.32.0
>            Reporter: Josh Byster
>            Priority: Major
>
> Federated queues with A upstream and downstream to B do not seem to work as 
> expected when the client JMS implementation is ActiveMQ Classic v5.16.2 (used 
> in my example, but also verified the issue is present with v5.18.3 and 
> v6.0.1). With Artemis JMS as the client, it seems to work as expected.
> When running a producer on A and a consumer on B with the classic 
> org.apache.activemq.ActiveMQConnectionFactory, the consumer on B does not 
> consume any messages that the producer sends. When B is restarted, it then 
> consumes the messages.
> This works properly with ActiveMQ Artemis 
> org.apache.activemq.artemis.jms.client.ActiveMQConnectionFactory. I've 
> created a minimal reproducible example 
> [here|https://github.com/josh-byster/artemis-classic-consumer-bug/tree/master].
>  Running server1 and server2 and then first starting up the Consumer then 
> running the Producer class, we can see that no messages are logged in console 
> by the consumer. When you restart the consumer, the messages are consumed. 
> This is an issue whether you attach a MessageListener or you call receive() 
> directly. If you switch the ActiveMQConnectionFactory implementation to 
> Artemis, it works as expected.
> I don't think this necessarily warrants a fix if it's an issue specifically 
> with the classic client, since the solution is just to upgrade clients to 
> Artemis. However, if it is something that can be patched on the server, that 
> would be great. I do, however, think it would be good to note this down in 
> the docs that it's not supported with classic clients, since I spent a while 
> debugging it. However, most other features do work as expected with the 
> clients running the classic version, which is much appreciated as it makes 
> migration significantly easier.
>  



--
This message was sent by Atlassian Jira