mark1russell7 opened a new issue, #549:
URL: https://github.com/apache/arrow-js/issues/549

   ### Describe the bug, including details regarding any error messages, 
version, and platform.
   
   The IPC reader ignores `Schema.endianness`. A stream whose schema says Big, 
with its values in big-endian byte order, reads as little endian, with no byte 
swap and no error. The repro makes such a stream of the int32 values `[1, 2, 
3]`, as a big-endian producer writes it. `tableFromIPC` returns `[16777216, 
33554432, 50331648]`.
   
   The format lets a reader byte-swap such data or refuse it. Arrow C++ 
byte-swaps it by default (`IpcReadOptions::ensure_native_endian` in 
`cpp/src/arrow/ipc/options.h`), so Arrow C++ and Arrow JS give different values 
for the same bytes. The Arrow JS writer itself writes `Endianness.Big` on a 
big-endian platform (`src/ipc/metadata/message.ts` line 607), so a stream from 
Arrow JS on such a platform also reads wrong on a little-endian platform.
   
   **Version and platform:** `apache-arrow` 21.2.0, Node.js 24.21.0 on Windows 
11. The code below is the same on `main` (5aa0205).
   
   **Repro.** Save as `repro.ts`, install `[email protected]` and 
`[email protected]` (the version that apache-arrow installs), and run `node 
repro.ts` (Node.js 24 strips the types). It exits 1 while the fault is present.
   
   ```ts
   // apache-arrow 21.2.0. The reader ignores Schema.endianness. decodeSchema() 
does not read the field, so a stream from
   // a big-endian producer (Schema.endianness = Big, values in big-endian byte 
order) reads as little endian, with no
   // error and no byte swap. The int32 values 1, 2 and 3 read as 16777216, 
33554432 and 50331648.
   import * as A from "apache-arrow";
   import { Message } from "apache-arrow/fb/message";
   import { Schema } from "apache-arrow/fb/schema";
   import * as flatbuffers from "flatbuffers";
   
   const values = Int32Array.of(1, 2, 3);
   const stream = A.tableToIPC(A.tableFromArrays({ x: values }), "stream");
   
   // The Schema message is first and has no body. The RecordBatch message 
follows, then the end-of-stream marker.
   const view = new DataView(stream.buffer, stream.byteOffset, 
stream.byteLength);
   const batchStart = 8 + view.getInt32(4, true);
   const batchMetadataLength = view.getInt32(batchStart + 4, true);
   const batchBodyStart = batchStart + 8 + batchMetadataLength;
   const batchBodyLength = Number(A.Message.decode(stream.subarray(batchStart + 
8, batchBodyStart)).bodyLength);
   const batchEnd = batchBodyStart + batchBodyLength;
   
   // A Schema message with the same fields and Schema.endianness = Big (1), as 
a big-endian producer writes it. The
   // little-endian writer leaves out the field (Little is the default), so 
there is no byte to change.
   const builder = new flatbuffers.Builder(256);
   const schema = A.tableFromIPC(stream).schema;
   const fields = Schema.createFieldsVector(builder, schema.fields.map((field) 
=> (A.Field as any).encode(builder, field)));
   Schema.startSchema(builder);
   Schema.addFields(builder, fields);
   Schema.addEndianness(builder, 1);
   const schemaOffset = Schema.endSchema(builder);
   Message.startMessage(builder);
   Message.addVersion(builder, A.MetadataVersion.V5);
   Message.addHeaderType(builder, A.MessageHeader.Schema);
   Message.addHeader(builder, schemaOffset);
   Message.addBodyLength(builder, 0n);
   Message.finishMessageBuffer(builder, Message.endMessage(builder));
   const flatbuffer = builder.asUint8Array();
   const metadata = new Uint8Array(Math.ceil((flatbuffer.length + 8) / 8) * 8 - 
8);
   metadata.set(flatbuffer);
   const bigEndianSchema = new Uint8Array(8 + metadata.length);
   new DataView(bigEndianSchema.buffer).setInt32(0, -1, true);
   new DataView(bigEndianSchema.buffer).setInt32(4, metadata.length, true);
   bigEndianSchema.set(metadata, 8);
   
   // The same RecordBatch message, with the 3 int32 values of its body in 
big-endian byte order. The metadata (the
   // flatbuffer) stays little endian, as the format says.
   const bigEndianBatch = stream.slice(batchStart, batchEnd);
   const batchView = new DataView(bigEndianBatch.buffer);
   for (let i = 0; i < values.length; i++) batchView.setInt32(batchBodyStart - 
batchStart + 4 * i, values[i]!, false);
   
   const bigEndianStream = new Uint8Array([...bigEndianSchema, 
...bigEndianBatch, ...stream.subarray(batchEnd)]);
   const decoded = Message.getRootAsMessage(new 
flatbuffers.ByteBuffer(bigEndianStream.slice(8, 8 + metadata.length)));
   console.log(`Schema.endianness of the changed stream: ${(decoded.header(new 
Schema()) as Schema).endianness()} (0 = Little, 1 = Big)`);
   
   const read = (bytes: Uint8Array): string => {
     try {
       const table = A.tableFromIPC(bytes);
       return `${table.numRows} rows, x = 
${JSON.stringify(Array.from(table.getChild("x") ?? []))}`;
     } catch (error) {
       return `throws: ${(error as Error).message}`;
     }
   };
   
   console.log(`little-endian stream: ${read(stream)}`);
   const result = read(bigEndianStream);
   console.log(`big-endian stream: ${result}`);
   
   if (!result.startsWith("throws") && !result.includes("x = [1,2,3]")) {
     console.log("BUG PRESENT: a stream with Schema.endianness = Big reads as 
little endian, with no byte swap and no error.");
     process.exit(1);
   }
   console.log("OK: the reader byte-swaps the big-endian stream, or refuses 
it.");
   ```
   
   **Output:**
   
   ```
   Schema.endianness of the changed stream: 1 (0 = Little, 1 = Big)
   little-endian stream: 3 rows, x = [1,2,3]
   big-endian stream: 3 rows, x = [16777216,33554432,50331648]
   BUG PRESENT: a stream with Schema.endianness = Big reads as little endian, 
with no byte swap and no error.
   exit code: 1
   ```
   
   **Expected:** `[1, 2, 3]` (the reader byte-swaps the buffers), or an error 
that says that the reader does not support a big-endian stream on this platform.
   
   **Cause:** `decodeSchema()` in `src/ipc/metadata/message.ts` (lines 351 to 
354) reads the fields and the custom metadata of the schema, but not 
`_schema.endianness()`. The `Schema` class has no field for it, and the record 
batch loader always reads the buffers in platform byte order.
   
   
https://github.com/apache/arrow-js/blob/5aa020540217b1aef9571cd3c9473627cd909e2f/src/ipc/metadata/message.ts#L351-L354
   
   **Possible fix:** Read `_schema.endianness()` in `decodeSchema()`. When it 
is not the platform byte order, throw an error that names the endianness. A 
later change can byte-swap the fixed-width buffers in the loader instead, as 
Arrow C++ does.
   
   An AI coding assistant (Claude Code) found this fault, wrote the repro and 
wrote this text.
   
   ### Component(s)
   
   JavaScript
   


-- 
This is an automated message from the Apache Git Service.
To respond to the message, please log on to GitHub and use the
URL above to go to the specific comment.

To unsubscribe, e-mail: [email protected]

For queries about this service, please contact Infrastructure at:
[email protected]

Reply via email to