https://issues.apache.org/jira/browse/AURORA-787?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=14177621#comment-14177621
 ] 

Maxim Khutornenko commented on AURORA-787:
------------------------------------------

To clarify, killing an instance should not use a {{maxWaitToInstanceRunningMs}} 
timeout, which is user-defined and may be set too low. We should either use a 
completely different value or possibly relying on a 
{{transient_task_state_timeout}}.

> Avoid using maxWaitToInstanceRunningMs for instance killing wait
> ----------------------------------------------------------------
>
>                 Key: AURORA-787
>                 URL: https://issues.apache.org/jira/browse/AURORA-787
>             Project: Aurora
>          Issue Type: Bug
>          Components: Scheduler
>            Reporter: Maxim Khutornenko
>
> The {{maxWaitToInstanceRunningMs}} is user controlled and may be set too low 
> for the instance killing to succeed. Use a system defined fixed timeout 
> instead.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)