https://issues.apache.org/jira/browse/BEAM-14265?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=17525890#comment-17525890
]
Kenneth Knowles commented on BEAM-14265:
----------------------------------------
Does it ignore the value (a data correctness bug) or does it reject the
pipeline or fail at runtime?
> Flink should hold the watermark at the output timestamp for processing time
> timers
> ----------------------------------------------------------------------------------
>
> Key: BEAM-14265
> URL: https://issues.apache.org/jira/browse/BEAM-14265
> Project: Beam
> Issue Type: Bug
> Components: runner-flink
> Reporter: Steve Niemitz
> Priority: P2
>
> Currently the Flink runner doesn't support output timestamps on processing
> time timers, and instead uses the current output watermark when the timer
> fires.
> We should update the runner to correctly set a watermark hold at the output
> timestamp and use it when firing the timer.
--