https://issues.apache.org/jira/browse/BEAM-8901?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16989561#comment-16989561
]
Maximilian Michels commented on BEAM-8901:
------------------------------------------
This shouldn't be necessary. Flink itself runs thousands of these tests without
any OOM issues. The embedded cluster shuts down after the pipeline finishes and
releases the memory. Rather, the symptom means that there is a memory leak
induced through Beam on Flink.
> add experimental flag for reusing flink local environment
> ---------------------------------------------------------
>
> Key: BEAM-8901
> URL: https://issues.apache.org/jira/browse/BEAM-8901
> Project: Beam
> Issue Type: Improvement
> Components: runner-flink
> Reporter: Heejong Lee
> Assignee: Heejong Lee
> Priority: Major
> Time Spent: 0.5h
> Remaining Estimate: 0h
>
> Flink job server launches a new mini cluster every time we run the pipeline
> on Flink local environment. To prevent OOM, we need to reuse existing Flink
> local environment if possible.
--
This message was sent by Atlassian Jira
(v8.3.4#803005)