https://issues.apache.org/jira/browse/CALCITE-3435?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16963351#comment-16963351
]
Julian Hyde commented on CALCITE-3435:
--------------------------------------
While the standard only allows integers, it seems reasonable to extend to allow
decimal or numeric with other scale. (I'm not sure we should allow
floating-point.) Please propose a type inference rule for these types that is
consistent with the standard's rule.
> floor(mod(33.5,7)) wrongly returns 5.5
> --------------------------------------
>
> Key: CALCITE-3435
> URL: https://issues.apache.org/jira/browse/CALCITE-3435
> Project: Calcite
> Issue Type: Bug
> Affects Versions: 1.16.0, 1.21.0
> Reporter: jiezouSH
> Assignee: Feng Zhu
> Priority: Minor
>
> mod's return type is
> chain(DECIMAL_MOD_NULLABLE, ARG1_NULLABLE),
> but mod(33.5,7)'s result is 5.5, not in line with ARG1_NULLABLE.
> This causes floor(mod(33.5,7)) wrongly returns 5.5
--
This message was sent by Atlassian Jira
(v8.3.4#803005)