Henryk Konsek created CAMEL-8450:
------------------------------------

             Summary: Netty component should not stop/null static timer when 
stopping
                 Key: CAMEL-8450
                 URL: https://issues.apache.org/jira/browse/CAMEL-8450
             Project: Camel
          Issue Type: Bug
          Components: camel-netty
            Reporter: Henryk Konsek
            Assignee: Henryk Konsek
             Fix For: 2.15.0


{{NettyComponent.timer}} is static. It is initialized/started on component 
startup and stopped/nulled on component shutdown. The static timer is shared 
between. It means that when you start two bundles using camel-netty and then 
stop one of it, then the remaining running bundle will not be able to create 
new endpoints dynamically, because of the nulled timer in the component (until 
some other bundle using Netty component is started and reinitalizes the timer 
again).

IMHO, we should not stop neither null the static timer. It can be shared 
between components and initialized/started when the first {{NettyComponent}} 
instance is created, but it should last forever. We technically could count the 
number of the component instances, and stops the timer when there is no 
{{NettyComponent}} available, but I don't see a point in this kind of 
micro-optimization. This is only one timer instance per application.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to