Thomas O'Dowd created CLOUDSTACK-3211:
-----------------------------------------

             Summary: Object_Store_Refactor - S3 GUI timeout units are unclear
                 Key: CLOUDSTACK-3211
                 URL: https://issues.apache.org/jira/browse/CLOUDSTACK-3211
             Project: CloudStack
          Issue Type: Bug
      Security Level: Public (Anyone can view this level - this is the default.)
    Affects Versions: 4.2.0
         Environment: devcloud
Cloudian or AWS S3 services.
            Reporter: Thomas O'Dowd


Connection Timeout:
Socket Timeout:

The units for these are unclear. I assumed they were seconds but now I think 
they might be milliseconds. 

When I added S3 secondary storage to a local Cloudian S3 server, I was setting 
60 for the connection timeout and it was ok. However, when I set 60 for the 
same timeout when adding the S3 server, I could never manage to upload a 
template. So I suspect that the connection was taking longer to setup. No 
errors are logged which is another problem but when I changed the timeouts to 
60000, I could finally get a template uploaded to AWS.

The gui should be clear regarding the units and provide help if possible.

--
This message is automatically generated by JIRA.
If you think it was sent incorrectly, please contact your JIRA administrators
For more information on JIRA, see: http://www.atlassian.com/software/jira