https://issues.apache.org/jira/browse/NET-262?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=12681111#action_12681111
]
Rory Winston commented on NET-262:
----------------------------------
I should be more explicit about the bounds - I'll fix up the docs.
The 192.168.0.3/31 addresses=0 example is actually correct with the assumed
bounds - it doesnt count the network and broadcast address as usable. I'll look
at the range check -I'm not sure that the current impl is 100% correct.
> SubnetUtils does not handle /31 and /32 CIDRs well
> --------------------------------------------------
>
> Key: NET-262
> URL: https://issues.apache.org/jira/browse/NET-262
> Project: Commons Net
> Issue Type: Bug
> Affects Versions: 2.0
> Reporter: Sebb
>
> SubnetUtils does not handle /31 and /32 CIDRs well.
> This should be documented and/or fixed.
> 192.168.0.1/32 causes an IllegalArgumentException to be thrown (by the way,
> that should show the upper and lower bounds)
> 192.168.0.3/31 gives
> addressCount=0,
> low =192.168.0.3
> high=192.168.0.2
> and 192.168.0.3 is rejected as not in range
--
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.