https://issues.apache.org/jira/browse/EXEC-33?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=12700560#action_12700560
]
Siegfried Goeschl commented on EXEC-33:
---------------------------------------
Milos, I'm completely busy the next few days so it looks like next weekend for
the patch .... :-(
> PumpStreamHandler hangs if System.in is redirect to process input stream
> ------------------------------------------------------------------------
>
> Key: EXEC-33
> URL: https://issues.apache.org/jira/browse/EXEC-33
> Project: Commons Exec
> Issue Type: Bug
> Affects Versions: 1.0.0
> Environment: Windows Vista
> Reporter: Marco Ferrante
> Assignee: Siegfried Goeschl
> Priority: Minor
> Attachments: EXEC33.patch, PumpStreamHandler.patch
>
>
> When process input is redirected using a PumpStreamHandler, e.g.
> PumpStreamHandler streamHanlder = new PumpStreamHandler(out, err,
> System.in);
> exec.setStreamHandler(streamHanlder);
> MockExecuteResultHandler handler = new MockExecuteResultHandler();
> exec.execute(cl, handler);
> the process hangs and never exit.
--
This message is automatically generated by JIRA.
-
You can reply to this email to add a comment to the issue online.