https://issues.apache.org/jira/browse/COMPRESS-161?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Stefan Bodewig resolved COMPRESS-161.
-------------------------------------
Resolution: Duplicate
Fix Version/s: (was: 1.3)
1.4
This is COMPRESS-146 which has just been fixed.
In order to make it work you must use the new two-arg constructor of the stream
and pass in true as second argument.
> bzip2 decompression terminates after 900000 bytes
> -------------------------------------------------
>
> Key: COMPRESS-161
> URL: https://issues.apache.org/jira/browse/COMPRESS-161
> Project: Commons Compress
> Issue Type: Bug
> Components: Compressors
> Affects Versions: 1.3
> Environment: Windows7 64bit JDK7u1,2
> Reporter: Hans horn
> Priority: Critical
> Fix For: 1.4
>
> Attachments: INT1_aminey.inp.bz2
>
>
> bzip2 decompression terminates (w/o error) after 900000 bytes
> try {
> InputStream iin = new BZip2CompressorInputStream(new
> FileInputStream(bzip2 compressed file that was uncompressed > 900000 bytes in
> size);
> int data = iin.read();
> while (data != -1) {
> System.out.print((char) data); ++nBytes;
> data = iin.read();
> }
> } catch (IOException iox) { /**/ }
> System.out.println("#Bytes read " + nBytes);
> prints: #Bytes read 900000
--