Victor Romero created NET-523:
---------------------------------

             Summary: SubnetUtils constructor fails on /32 subnets
                 Key: NET-523
                 URL: https://issues.apache.org/jira/browse/NET-523
             Project: Commons Net
          Issue Type: Bug
    Affects Versions: 2.0
         Environment: All
            Reporter: Victor Romero
             Fix For: 2.2


The following code:

SubnetUtils subnetUtils = new SubnetUtils("192.168.0.1/32");

throws the following exception:

Exception in thread "main" java.lang.IllegalArgumentException: Value [32] not 
in range (-1,31]
        at 
org.apache.commons.net.util.SubnetUtils.rangeCheck(SubnetUtils.java:216)
        at 
org.apache.commons.net.util.SubnetUtils.calculate(SubnetUtils.java:141)
        at org.apache.commons.net.util.SubnetUtils.<init>(SubnetUtils.java:46)
        at com.gs.configmgt.proteus.model.impl.TestTest.main(TestTest.java:12)

/32 is a perfectly valid subnet of one host. See wikipedia for verification: 
http://en.wikipedia.org/wiki/IPv4_subnetting_reference.



--
This message was sent by Atlassian JIRA
(v6.1.5#6160)

Reply via email to