https://issues.apache.org/jira/browse/CXF-3214?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Willem Jiang resolved CXF-3214.
-------------------------------
Resolution: Fixed
> CXFBusLifeCycleManager will call the preshutdown twice if when the
> BusApplicationContext is closed
> --------------------------------------------------------------------------------------------------
>
> Key: CXF-3214
> URL: https://issues.apache.org/jira/browse/CXF-3214
> Project: CXF
> Issue Type: Bug
> Components: Core
> Affects Versions: 2.1.10, 2.0.13, 2.2.10, 2.3.0, 2.2.11, 2.2.12, 2.3.1
> Reporter: Willem Jiang
> Assignee: Willem Jiang
> Priority: Minor
> Fix For: 2.3.2, 2.2.13, 2.4
>
>
> When I write the test of BusApplicationListenerTest I found the
> BusLifeCycleListener will be called twice when the application context is
> closed.
> The code of CXFBusLifeCycleManager should be changed like this
> {code}
> ---
> rt/core/src/main/java/org/apache/cxf/buslifecycle/CXFBusLifeCycleManager.java
> (revision 1051771)
> +++
> rt/core/src/main/java/org/apache/cxf/buslifecycle/CXFBusLifeCycleManager.java
> (working copy)
> @@ -78,9 +78,11 @@
>
> public void preShutdown() {
> // TODO inverse order of registration?
> - preShutdownCalled = true;
> - for (BusLifeCycleListener listener : listeners) {
> - listener.preShutdown();
> + if (!preShutdownCalled) {
> + preShutdownCalled = true;
> + for (BusLifeCycleListener listener : listeners) {
> + listener.preShutdown();
> + }
> }
> }
> {code}
--
This message is automatically generated by JIRA.
-