Chris Westin created DRILL-2656:
-----------------------------------

             Summary: Add ability to specify options for clean shutdown of a 
Drillbit
                 Key: DRILL-2656
                 URL: https://issues.apache.org/jira/browse/DRILL-2656
             Project: Apache Drill
          Issue Type: New Feature
          Components: Execution - Flow
    Affects Versions: 0.8.0
            Reporter: Chris Westin
            Assignee: Chris Westin
             Fix For: 1.0.0


When we shut down a Drillbit, we should provide some options similar to those 
available from Oracle's shutdown command (see 
https://docs.oracle.com/cd/B28359_01/server.111/b28310/start003.htm#ADMIN11156) 
.

At present, in order to avoid problems like DRILL-2654, we try to do a short 
wait for executing queries, but that times out after 5 seconds, and doesn't 
help with long-running queries.

Someone that is running a long query might be unhappy about losing work for 
something that was near completion, so we can do better.

And, in order to avoid spurious cleanup problems and exceptions, we should 
explicitly cancel any remaining queries before we do complete the shutdown.

As in the Oracle example, we might have shutdown immediate issue cancellations 
to the running queries.  A clean shutdown might not have a timeout, or might 
allow the specification of a longer timeout, and even when the timeout goes 
off, we should still cleanly cancel any remaining queries, and wait for the 
cancellations to complete.




--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to