https://issues.apache.org/jira/browse/DRILL-4764?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15715899#comment-15715899
]
ASF GitHub Bot commented on DRILL-4764:
---------------------------------------
Github user parthchandra commented on a diff in the pull request:
https://github.com/apache/drill/pull/673#discussion_r90694144
--- Diff:
exec/java-exec/src/main/java/org/apache/drill/exec/store/parquet/columnreaders/ParquetFixedWidthDictionaryReaders.java
---
@@ -56,6 +58,31 @@ protected void readField(long recordsToReadInThisPass) {
}
}
+ /**
+ * This class uses for reading unsigned integer fields.
+ */
+ static class DictionaryUInt4Reader extends
FixedByteAlignedReader<UInt4Vector> {
+ DictionaryUInt4Reader(ParquetRecordReader parentReader, int
allocateSize, ColumnDescriptor descriptor,
+ ColumnChunkMetaData columnChunkMetaData, boolean
fixedLength, UInt4Vector v,
+ SchemaElement schemaElement) throws
ExecutionSetupException {
+ super(parentReader, allocateSize, descriptor, columnChunkMetaData,
fixedLength, v, schemaElement);
+ }
+
+ // this method is called by its superclass during a read loop
+ @Override
+ protected void readField(long recordsToReadInThisPass) {
+
+ recordsReadInThisIteration = Math.min(pageReader.currentPageCount
+ - pageReader.valuesRead, recordsToReadInThisPass -
valuesReadInCurrentPass);
+
+ if (usingDictionary) {
+ for (int i = 0; i < recordsReadInThisIteration; i++){
+ valueVec.getMutator().setSafe(valuesReadInCurrentPass + i,
pageReader.dictionaryValueReader.readInteger());
--- End diff --
you probably need to set writer index just as you do in the uint8 case.
> Parquet file with INT_16, etc. logical types not supported by simple SELECT
> ---------------------------------------------------------------------------
>
> Key: DRILL-4764
> URL: https://issues.apache.org/jira/browse/DRILL-4764
> Project: Apache Drill
> Issue Type: Bug
> Components: Execution - Data Types
> Affects Versions: 1.6.0
> Reporter: Paul Rogers
> Assignee: Parth Chandra
> Attachments: int_16.parquet, int_8.parquet, uint_16.parquet,
> uint_32.parquet, uint_8.parquet
>
>
> Create a Parquet file with the following schema:
> message int16Data { required int32 index; required int32 value (INT_16); }
> Store it as int_16.parquet in the local file system. Query it with:
> SELECT * from `local`.`root`.`int_16.parquet`;
> The result, in the web UI, is this error:
> org.apache.drill.common.exceptions.UserRemoteException: SYSTEM ERROR:
> UnsupportedOperationException: unsupported type: INT32 INT_16 Fragment 0:0
> [Error Id: c63f66b4-e5a9-4a35-9ceb-546b74645dd4 on 172.30.1.28:31010]
> The INT_16 logical (or "original") type simply tells consumers of the file
> that the data is actually a 16-bit signed int. Presumably, this should tell
> Drill to use the SmallIntVector (or NullableSmallIntVector) class for
> storage. Without supporting this annotation, even 16-bit integers must be
> stored as 32-bits within Drill.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)