https://issues.apache.org/jira/browse/FLINK-6853?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Tzu-Li (Gordon) Tai closed FLINK-6853.
--------------------------------------

> Migrating from Flink 1.1 fails for FlinkCEP
> -------------------------------------------
>
>                 Key: FLINK-6853
>                 URL: https://issues.apache.org/jira/browse/FLINK-6853
>             Project: Flink
>          Issue Type: Bug
>          Components: CEP
>    Affects Versions: 1.3.0
>            Reporter: Tzu-Li (Gordon) Tai
>            Assignee: Tzu-Li (Gordon) Tai
>             Fix For: 1.3.1, 1.4.0
>
>
> Migrating from Flink 1.1 fails for CEP, since in 1.1, the legacy 
> {{MultiplexingStreamRecordSerializer}} is used for stream  elements in the 
> serialized priority queue (via the {{PriorityQueueSerializer}}).
> In newer versions, the {{StreamElementSerializer}} is used instead. For this 
> to work, we need to implement the compatibility methods for 
> {{StreamElementSerializer}} such that it is also compatible with 
> configuration snapshots taken from the {{MultiplexingStreamRecordSerializer}}.



--