Github user godfreyhe commented on a diff in the pull request:
https://github.com/apache/flink/pull/3860#discussion_r138843966
--- Diff:
flink-libraries/flink-table/src/main/scala/org/apache/flink/table/plan/nodes/PhysicalTableSourceScan.scala
---
@@ -70,4 +73,18 @@ abstract class PhysicalTableSourceScan(
def copy(traitSet: RelTraitSet, tableSource: TableSource[_]):
PhysicalTableSourceScan
+ override def estimateRowCount(mq: RelMetadataQuery): Double = {
+ val tableSourceTable = getTable.unwrap(classOf[TableSourceTable[_]])
+
+ if (tableSourceTable.getStatistic != FlinkStatistic.UNKNOWN) {
--- End diff --
hi @fhueske, so sorry for late response. Some time ago, my work focus is
not on Table API & SQL, now I will refocus on it.
There are mainly 4 cases:
1. `DataSetTable` or `DataStreamTable`, default statistics (row count =
1000).
2. `TableSourceTable` is registered without catalog, no statistic now. (we
can get statistics from `TableSource`)
3. `TableSourceTable` is in catalog, and the catalog constains statistics.
3.1. If the `TableSource` is filterable (or partitionable) TableSource,
maybe we can not use the catalog's statistics any more, should use
`TableSource` statistics. (such as Parquet table source)
3.2 If the `TableSource` is non-filterable (or non-partitionable)
TableSource, we are prefer catalog's statistics because of more efficient
access.
4. `TableSourceTable` is in catalog, but the catalog does not have
statistics. (get statistics from `TableSource`)
Furthermore, the statistics in catalog may be wrong, someone want the
statistics from `TableSource`.
So, it's too difficult to let framework choose the statistics source. I
prefer that let user choose the statistics source. There are two approach:
1. a simple way: add config(`var preferCatalogStats: Boolean`) in
`TableConfig`, user can choose prefer statistics source by table config. If
`preferCatalogStats` is true, framework will use catalog statistics first; if
the statistics is null (or unknown), framework use `TableSource` statistics. If
`preferCatalogStats` is false, the access order will be reversed.
2. a complex way: Let user decide the statistics source when register the
table. We can change the `registerTable` and `registerTableSource` methods in
`TableEnvironment`:
```
// register table with statistic, the framework will always use the given
statistic.
def registerTable(name: String, table: Table, statistic =
FlinkStatistic.of(TableStats(1000L)))
// register table source with user prefer statistics source.
def registerTableSource(name: String, tableSource: TableSource[_],
preferCatalogStats: Boolean=false): Unit
// register table source with statistic, the framework will always use the
given statistic.
def registerTableSource(name: String, tableSource: TableSource[_],
statistic: FlinkStatistic): Unit
```
So, user can choose statistics source and add more accurate statistics for
each table.
Looking forward to your advice, many thanks!
---