https://issues.apache.org/jira/browse/FLINK-2294?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=14608236#comment-14608236
]
Robert Metzger commented on FLINK-2294:
---------------------------------------
It would have been nice if you waited until you reached agreement with Aljoscha
on the implementation, instead of just committing it to master, without a pull
request.
>From my understanding, I agree with Guyla, that it is easier to set the
>nextInput outside the operator, instead of inside all operators.
> Keyed State does not work with DOP=1
> ------------------------------------
>
> Key: FLINK-2294
> URL: https://issues.apache.org/jira/browse/FLINK-2294
> Project: Flink
> Issue Type: Bug
> Components: Streaming
> Affects Versions: 0.10
> Reporter: Aljoscha Krettek
> Assignee: Gyula Fora
> Priority: Blocker
>
> When changing the DOP from 3 to 1 in StatefulOperatorTest.apiTest() the test
> fails. The reason seems to be that the element is not properly set when
> chaining is happening.
> Also, requiring this:
> {code}
> headContext.setNextInput(nextRecord);
> streamOperator.processElement(nextRecord);
> {code}
> to be called seems rather fragile. Why not set the element in
> {{processElement()}}. This would also make for cleaner encapsulation, since
> now all outside code must assume that operators have a
> {{StreamingRuntimeContext}} on which they set the next element.
> The state/keyed state machinery seems dangerously undertested.
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)