https://issues.apache.org/jira/browse/FLINK-7456?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16324468#comment-16324468
]
ASF GitHub Bot commented on FLINK-7456:
---------------------------------------
Github user NicoK commented on a diff in the pull request:
https://github.com/apache/flink/pull/4552#discussion_r161242036
--- Diff:
flink-runtime/src/main/java/org/apache/flink/runtime/io/network/netty/SequenceNumberingViewReader.java
---
@@ -49,10 +50,24 @@
private volatile ResultSubpartitionView subpartitionView;
+ /**
+ * The status indicating whether this reader is already enqueued in the
pipeline for transferring
+ * data or not. It is mainly used for avoid registering this reader to
the pipeline repeatedly.
+ */
+ private boolean isRegisteredAvailable;
--- End diff --
I know it's default-initialized to false but let's make this explicit
> Implement Netty sender incoming pipeline for credit-based
> ---------------------------------------------------------
>
> Key: FLINK-7456
> URL: https://issues.apache.org/jira/browse/FLINK-7456
> Project: Flink
> Issue Type: Sub-task
> Components: Network
> Reporter: zhijiang
> Assignee: zhijiang
> Fix For: 1.5.0
>
>
> This is a part of work for credit-based network flow control.
> On sender side, each subpartition view maintains an atomic integer
> {{currentCredit}} from receiver. Once receiving the messages of
> {{PartitionRequest}} and {{AddCredit}}, the {{currentCredit}} is added by
> deltas.
> Each view also maintains an atomic boolean field to mark it as registered
> available for transfer to make sure it is enqueued in handler only once. If
> the {{currentCredit}} increases from zero and there are available buffers in
> the subpartition, the corresponding view will be enqueued for transferring
> data.
--
This message was sent by Atlassian JIRA
(v6.4.14#64029)