https://issues.apache.org/jira/browse/FLINK-9113?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16425519#comment-16425519
 ] 

ASF GitHub Bot commented on FLINK-9113:
---------------------------------------

Github user twalthr commented on the issue:

    https://github.com/apache/flink/pull/5811
  
    @kl0u do you have an idea why `BucketingSinkTest` is failing? It seems that 
the written data parts are always empty.


> Data loss in BucketingSink when writing to local filesystem
> -----------------------------------------------------------
>
>                 Key: FLINK-9113
>                 URL: https://issues.apache.org/jira/browse/FLINK-9113
>             Project: Flink
>          Issue Type: Bug
>          Components: Streaming Connectors
>            Reporter: Timo Walther
>            Assignee: Timo Walther
>            Priority: Major
>
> This issue is closely related to FLINK-7737. By default the bucketing sink 
> uses HDFS's {{org.apache.hadoop.fs.FSDataOutputStream#hflush}} for 
> performance reasons. However, this leads to data loss in case of TaskManager 
> failures when writing to a local filesystem 
> {{org.apache.hadoop.fs.LocalFileSystem}}. We should use {{hsync}} by default 
> in local filesystem cases and make it possible to disable this behavior if 
> needed.



--
This message was sent by Atlassian JIRA
(v7.6.3#76005)

Reply via email to