Github user aljoscha commented on the issue:

    https://github.com/apache/flink/pull/6224
  
    Unfortunately, we cannot distinguish between cleanup timers and other 
timers. In fact, in the case where we have `allowed lateness = 0` the one timer 
is both a normal timer and a cleanup timer.


---