https://issues.apache.org/jira/browse/FLINK-8523?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=16558791#comment-16558791
]
ASF GitHub Bot commented on FLINK-8523:
---------------------------------------
NicoK commented on a change in pull request #5381: [FLINK-8523][network] Stop
assigning floating buffers for blocked input channels in exactly-once mode
URL: https://github.com/apache/flink/pull/5381#discussion_r205572300
##########
File path:
flink-runtime/src/main/java/org/apache/flink/runtime/io/network/partition/consumer/RemoteInputChannel.java
##########
@@ -360,8 +360,9 @@ public boolean notifyBufferAvailable(Buffer buffer) {
// Important: double check the isReleased state inside
synchronized block, so there is no
// race condition when notifyBufferAvailable and
releaseAllResources running in parallel.
- if (isReleased.get() ||
bufferQueue.getAvailableBufferSize() >= numRequiredBuffers) {
+ if (isReleased.get() || isBlocked() ||
bufferQueue.getAvailableBufferSize() >= numRequiredBuffers) {
Review comment:
Indeed, the "blocked" credits should be in `numRequiredBuffers` which was
updated with the last buffer that we received. Any update on that will come
with the next buffer. We just need to make sure that we acknowledge the newly
freed credit to the sender (the backlog may be 0).
The request for floating buffers should remain fair among all channels
though and therefore we cannot request all floating buffers to satisfy that
need at once!
----------------------------------------------------------------
This is an automated message from the Apache Git Service.
To respond to the message, please log on GitHub and use the
URL above to go to the specific comment.
For queries about this service, please contact Infrastructure at:
[email protected]
> Stop assigning floating buffers for blocked input channels in exactly-once
> mode
> -------------------------------------------------------------------------------
>
> Key: FLINK-8523
> URL: https://issues.apache.org/jira/browse/FLINK-8523
> Project: Flink
> Issue Type: Sub-task
> Components: Network
> Affects Versions: 1.5.0, 1.6.0
> Reporter: zhijiang
> Assignee: zhijiang
> Priority: Major
> Labels: pull-request-available
>
> In exactly-once mode, the input channel is set blocked state when reading
> barrier from it. And the blocked state will be released after barrier
> alignment or cancelled.
>
> In credit-based network flow control, we should avoid assigning floating
> buffers for blocked input channels because the buffers after barrier will not
> be processed by operator until alignment.
> To do so, we can fully make use of floating buffers and speed up barrier
> alignment in some extent.
--
This message was sent by Atlassian JIRA
(v7.6.3#76005)